MicroRhizons
pore water samplers for the RhizonBox
overview
MicroRhizons are mainly used in RhizonBox and agar tests.
They consist of two parts: a porous part of 8 mm with an outer diameter of 1 mm, and PEEK tubing with a connector fit to a syringe.
The yield of MicroRhizons is up to 2 ml. As the tubing of MicroRhizons consists of PEEK and a special glue, it is possible to steam-sterilize them.
RhizonBox
RhizonBoxes for a direct sampling of soil moisture in the rhizosphere during growth experiments or root research.
In the front plate, there are 2183 holes with a lateral distance of 5 mm, which allow direct sampling near the roots with MicroRhizons.
The dimensions of the RhizonBox are: height 33 cm, width 22 cm, depth 4 cm.
rhizon models
19.21.81 | 10 x MicroRhizon with an exposed porous part of 0.8 mm with an outer diameter of 1 mm, glued on 12 cm PEEK tubing 0.6*0.4 mm. The PEEK tubing has a 0.1 mm hole about 3 mm from top for sampling |
19.21.82 | 10 x MicroRhizon with an exposed porous part of 0.8 mm with an outer diameter of 1 mm, glued on 12 cm PEEK tubing 0.6*0.4 mm. The PEEK tubing has a 0.1 mm hole about 3 mm from top for sampling. This part is supplied with loose 5 cm PEEK tubing 1.6 mm OD, which is used as guide tubing to push your MicroRhizon into agar or other media |
accessories for MicroRhizons
19.21.84 | 5 cm PEEK tubing, 1.6 mm OD, guide tubing to push your MicroRhizon into agar or other media |
19.21.85 | 30 cm PEEK extension tubing 0.6*0.4 mm, 30 cm, including silicon connectors |
19.21.88 | 10 x Syringe PP with Luer tip, 5 ml |
19.31.80 | 1 x RhizonBox, for direct inserting of MicroRhizons, 33 x 22 cm |
specifications
basic characteristics
- Microfiltration membrane with a nominal pore size of 0.12 – 0.18 µm
- Hydrophilic membrane composed of a blend of polyvinylpyrrolidine and polyethersulfone
- Structure asymmetric/microporous
- High performance and a very good anti-fouling behaviour
- Suitable for filtatrion outside-in and inside-out
performance data
pH-range | 2 – 12 |
Temperature | 1 – 90ºC |
Pressure | -300 – +300 kPa |
solvent resistance
Solvent | Resistance |
Acids |
++ |
Bases |
++ |
Organic esters, ketones, ethers |
— |
Aliphatic alcohols |
+ |
Aliphatic hydrocarbons |
+ |
Halogenated hydrocarbons |
— |
Aromatic hydrocarbons |
— |
Polar organic solvents |
— |
Oils |
++ |
storage